Corrosion Behavior of TLM Titanium Alloy with ECAP Deformation
Yang Xirong;Wang Bingbing;Qiang Meng;Liu Xiaoyan;Luo Lei;Wang Jingzhong;
Abstract:
Ti-25Nb-3Zr-3Mo-2Sn(TLM) titanium alloy is a new type of sub-stable β-type medical titanium alloy without toxic elements and with excellent comprehensive mechanical properties independently researched and developed by Northwest Institute of Nonferrous Metals.With the advantages of low density,high yield stress,low modulus of elasticity,easy processing and molding,and lower cost,it has good application prospects in dental implants,bone and joint replacement materials,vascular stents,and other biomedical applications.In order to further optimize the modification and processing of this alloy,perfect its performance in corrosion,strength,elastic modulus,wear resistance,fatigue strength,etc.,and expand its application,this paper adopts the method of violent plastic deformation to prepare TLM titanium alloy ultrafine crystal materials.Strenuous plastic deformation(SPD) technology is currently recognized as an efficient way to prepare ultrafine crystalline materials,and is also an effective means to enhance the corrosion resistance of materials by refining the grain.Among many SPD methods,equal channel angular pressing(ECAP) is not only the most effective way to prepare three-dimensional large-size bulk fine-crystalline materials,but also has the advantages of a relatively simple process and low cost,and is one of the most promising SPD techniques for industrial application,which can improve the performance of metallic materials without changing the cross-sectional shape and the area of the object.area to improve the corrosion resistance of metallic materials.In this study,the composition(%,mass fraction) of TLM titanium alloy was Nb 25.8,Zr 2.96,Sn 2.03,Mo 3.08,Fe 0.02,C 0.02,O 0.044,N 0.003,and the rest of titanium,which was deformed by multiple ECAP passes at room temperature,with an internal mold angle Φ of 135° and an external arc angle ψ of 20°,and the selection of graphite and oil made by the group were used as lubricants,the press rod speed was 2.5 mm·s~(-1),the number of extrusion passes was 4,and the extrusion path was C-path.The solution samples are named ST,and ECAP deformation samples for passes 1,2,and 4 are named 1P,2P,and 4P.An electrochemical test system consisting of an electrochemical workstation,a three-electrode system,and a display device was used to test the corrosion properties of the specimens prepared by ECAP deformation.During the experiment,the working electrode was the test specimen,the auxiliary electrode was the platinum sheet electrode,the saturated calomel electrode was selected as the reference electrode,and the electrolyte solution was Hank's simulated body fluid,which was configured at a temperature of(36.5±0.5) ℃,and the final reagent maintainedpH value of 7.4 at 36.5 ℃.The microstructures of TLM titanium alloys without ECAP deformation and after ECAP were investigated by optical microscopy(OM),X-ray diffractometry(XRD),electron backscattering diffractometry(EBSD),and scanning electron microscopy(SEM).The results showed that the open-circuit potential,kinetic potential polarization curves,and alternating current impedance spectroscopy tests indicated that the open-circuit potentials of TLM titanium alloys in Hank's simulated body fluid environment all showed an increasing trend,with the lowest steady-state open-circuit potential for Sample ST and the highest steady-state open-circuit potential for Sample 4P.The impedance radius of ECAP deformed specimen was larger than that of Sample ST,and the radius gradually increased with the increase in the number of passes.The impedance spectra of TLM titanium alloys before and after deformation were fitted to an equivalent circuit using ZimpWin software,and the fitting results were good.After ECAP deformation,the number of corrosion pits in TLM titanium alloy was significantly less than that before deformation,and the oxygen content in the corrosion pits was significantly higher than that outside the corrosion pits.The passivation film was mainly an oxide formed by the oxygen in the air and the elements such as titanium and niobium,which effectively blocked the entry of the corrosive elements in the simulated body fluids.The tissues of Sample ST showed a coarse and equiaxial distribution,with the average grain size of about 50 μm.The grains were refined after the deformation of 1 pass.A large number of twins appeared inside the grains,mainly {332}<113> twins,and the number of {112}<111> twins was very small;after 2 passes of deformation,part of the grains were obviously elongated,with an increasing number of twins,and some twins penetrated through several grains,and{112}<111> twins were very few;after 4 passes of deformation,the grain deformation was very obvious,and the average size reached 7.1 μm.{112}<111> twins were still few.{112}<111> the number of twins increases,{332}<113> the number of twins decreases slightly,both parallel to each other and intersecting each other,making the twin morphology different.According to the classical Harris equation,texture coefficients value was obtained by calculating the weaving coefficient,and TC value of Sample ST was greater than 1 on(110) and(200) crystal planes,which indicated that there was a weak weaving on(110) and(200) crystal planes of TLM titanium alloy.After the first deformation,the titanium alloy hadan obvious selective orientation on(211) crystal plane,and the fabrication was stronger.TLM titanium alloy,after two deformations,had a strong fabrication on(110) crystal plane;after four deformations,TLM titanium alloy produced a selective orientation on(211) crystal plane,but the fabrication was weaker than that produced after one deformation.
Key Words: equal channel angular pressing(ECAP);Ti-25Nb-3Mo-3Zr-2Sn(TLM) titanium alloy;twins;corrosive properties
Foundation: 国家自然科学基金面上项目(51474170);; 国家基金培育专项(X20240094);; 陕西省自然科学基金面上项目(2026JC-YBMS-0586)资助
Authors: Yang Xirong;Wang Bingbing;Qiang Meng;Liu Xiaoyan;Luo Lei;Wang Jingzhong;
DOI: 10.13373/j.cnki.cjrm.XY25040019
References:
- [1] Xiao W L, Fu Y, Wang J X, Zeng D, Liang X W, Chen H, Zhao X Q, Ma Z L. Research progress of biomedical metastable β titanium alloys[J]. Materials Engineering, 2023, 51(2):52.(肖文龙, 付雨, 王俊帅, 曾达, 梁雄伟, 陈恒, 赵新青, 马朝利. 生物医用亚稳β钛合金的研究进展[J]. 材料工程, 2023, 51(2):52.)
- [2] Festas A, Ramos A, Davim J P. Machining of titanium alloys for medical application-a review[J]. Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 2021, 236(4): 309.
- [3] Bahl S, Suwas S, Chatterjee K. Comprehensive review on alloy design, processing, and performance of β Titanium alloys as biomedical materials[J]. International Materials Reviews, 2020, 66(2): 114.
- [4] Liu J Y, Li M G, Su S, Gao Y, Kang W W, Chen B. Microstructure and properties of porous medical titanium alloy implanted in bones with different Mo contents[J]. Chinese Journal of Rare Metals, 2025, 49(10): 1493.(刘俊逸, 李明骜, 苏苏, 高宇, 康文武, 陈彬 . Mo 元素对骨植入多孔医用钛合金组织及性能的影响[J]. 稀有金属, 2025, 49(10): 1493.)
- [5] Valkov S, Dechev D, Ivanov N, Bezdushnyi R, Ormanova M, Petrov P. Influence of beam power on Young's Modulus and friction coefficient of TiTa alloys formed by electron-beam surface alloying[J]. Metals, 2021, 11(8): 1246.
- [6] Sri Maha Vishnu D, Sure J, Liu Y, Vasant Kumar R, Schwandt C. Electrochemical synthesis of porous Ti-Nb alloys for biomedical applications[J]. Materials Science and Engineering: C, 2019, 96: 466.
- [7] Yu Z T, Yu S, Cheng J, Ma X Q. R&D and application status of new medical titanium alloy materials[J]. Acta Metallurgica Sinica, 2017, 53(10): 1238.(于振涛, 余森, 程军, 麻西群 . 新型医用钛合金材料的研发和应用现状[J]. 金属学报, 2017, 53(10): 1238.)
- [8] Yu Z T, Tian Y X, Yu S, Ma X Q. Research on new β-type TLM titanium alloy materials for orthopedics[J]. Chinese Journal of Clinical and Basic Research in Orthopedics, 2013, 5(1): 6.(于振涛, 田宇兴, 余森, 麻西群 . 新型骨科用β型TLM 钛合金材料研究[J]. 中国骨科临床与基础研究杂志, 2013, 5(1): 6.)
- [9] Yu Z T, Zhou L. Influence of martensitic transformation on mechanical compatibility of biomedical β type titanium alloy TLM[J]. Materials Science and Engineering: A, 2006, 438-440: 391.
- [10] Yu Z T, Zhou L, Niu J L, Cai Y R, Luo L J, Huang F Q. Beta type titanium alloys used in surgical implant materials[J]. Rare Metal Materials and Engineering, 2006, 35(1): 261.
- [11] Zhang H X, Wang X, Han Y, Cao Z Q, Zhang K, Wang Y. Influences of nano crystallization and Cr content on corrosion behavior of Co-Fe-Cr alloy in NaCl solutions[J]. Nonferrous Metals Science and Engineering, 2025, 16(4): 503.(张昊鑫, 王秀, 韩漾, 曹中秋, 张轲, 王艳 . 纳米化和Cr含量对Co-Fe-Cr合金在NaCl溶液中腐蚀行为的影响[J]. 有色金属科学与工程, 2025, 16(4): 503.)
- [12] Lei H X, Liu X Y, Wu Y Q, Yang X R, Qiang M. Effect of deformation temperature on microstructures and properties of TA15 titanium alloy by equal channel angular pressing[J]. Forging & Stamping Technology, 2025, 50(12): 168.(雷亨希, 刘晓燕, 武宇琪, 杨西荣, 强萌 . 变形温度对TA15钛合金ECAP组织和性能的影响[J]. 锻压技术, 2025, 50(12): 168.)
- [13] Valiev R Z, Krasilnikov N A, Tsenev N K. Plastic deformation of alloys with submicron-grained structure[J]. Materials Science & Engineering A, 1991, 137: 35.
- [14] Yang X R, Wang Z X, Luo L, Liu X Y, Wang J Z. Research progress on the preparation of ultrafine crystalline materials by novel ECAP process[J]. Chinese Journal of Rare Metals, 2025, 49(3): 413.(杨西荣, 王兆麟, 罗雷, 刘晓燕, 王敬忠 . 新型ECAP 工艺制备超细晶材料研究进展[J]. 稀有金属, 2025, 49(3): 413.)
- [15] Li Y Q, Zhang M J, Guo F F, Zhou T S, Liu D X. Influence of differential thermal-ECAP on microstructure and corrosion properties of TZK magnesium alloy[J]. Journal of Plasticity Engineering, 2024, 31(8): 58.(李亚琴, 张敏洁, 郭菲菲, 周田水, 刘德学 . 差热-等通道转角挤压工艺对TZK镁合金微观组织与腐蚀性能的影响[J]. 塑性工程学报, 2024, 31(8): 58.)
- [16] Avinash B, Brundaban P. Corrosion behavior of ultrafine grained titanium in simulated body fluid for implant application[J]. Trends Biomater, 2008, 22(1): 58.
- [17] Hashemi P M, Borhani E, Nourbakhsh M S. Commercially pure titanium modification to enhance corrosion behavior and osteoblast response by ECAP for biomedical applications[J]. Journal of Applied Biomaterials & Functional Materials, 2022, 20: 1.
- [18] Hoseini M, Shahryari A, Omanovic S, Szpunar J A. Comparative effect of grain size and texture on the corrosion behaviour of commercially pure titanium processed by equal channel angular pressing[J]. Corrosion Science, 2009, 51(12): 3064.
- [19] Shen X Q, Zhang Y Q, Jiang Y H, Zhou R. The electrochemical corrosion behavior of SPS sintered Ti-35Nb-7Zr-5Ta alloy in Hank's simulated artificial body fluids[J]. Corrosion Science and Protection Technology, 2016, 28(6): 543.(沈雪青, 张玉勤, 蒋业华, 周荣 . SPS 烧结Ti-35Nb-7Zr-5Ta合金在Hank's 模拟人工体液中的电化学腐蚀行为[J]. 腐蚀科学与防护技术, 2016, 28(6): 543.)
- [20] Luo L, Duan X M, Ma W J, Yang X R, Liu X Y, Wang J Z. Effect of ECAP on microstructure and corrosion resistance properties of SLM pure titanium[J]. Rare Metal Materials and Engineering, 2022, 51(7): 2420.
- [21] Yu Y M. Study on Corrosion and Wear Behavior of Medical TLM Titanium Alloy in Protein-Containing Simulated Body Fluids[D]. Chongqing: Chongqing University of Technology, 2013. 67.(余永梅 . 医用TLM钛合金在含蛋白质模拟体液中的腐蚀与磨损行为研究[D]. 重庆: 重庆理工大学, 2013. 67.)
- [22] Liu X, Zhang H Y, Wang S Y, Zhou G, Cheng J, Chen L J. Effect of stress corrosion behavior of relative metastable β titanium alloy Ti-5.5Cr-5Al-4Mo-3Nb-2Zr in 3.5% NaCl solution in α[J]. Journal of Rare Metal Materials and Engineering, 2025, 54(1): 209.(刘璇, 张浩宇, 王圣元, 周舸, 程军, 陈立佳 . α 相对 亚稳 β 钛合金Ti-5.5Cr-5Al-4Mo-3Nb-2Zr在3.5% NaCl 溶液中应力腐蚀行为的影响[J]. 稀有金属材料与工程, 2025, 54(1): 209.)
- [23] Rong Y H, Zhu J, Wu J P, Xie L F, Li L Y. Electrochemical corrosion of Ti-3Ta-x Nb alloy in boiling nitric acid[J]. Titanium Industry Progress, 2023, 40(2): 25.(荣宇航, 朱杰, 吴金平, 谢龙飞, 李兰云 . Ti-3Ta-x Nb 合金在沸腾硝酸中的电化学腐蚀研究[J]. 钛工业进展, 2023, 40(2): 25.)
- [24] Dai N, Zhang LC, Zhang J, Zhang X, Ni Q, Chen Y, Wu M, Yang C. Distinction in corrosion resistance of selective laser melted Ti-6Al-4V alloy on different planes[J]. Corrosion Science, 2016, 111: 703.
- [25] Wang X M. Effect of ultrafine grain boundaries on metal corrosion properties[J]. Corrosion and protection, 2015, 36(8): 695.(王晓梅 . 超细晶界对金属腐蚀性能的影响[J]. 腐蚀与防护, 2015, 36(8): 695.)
- [26] Qiang M, Yang X R, Liu X Y, Luo L. Progress of ultrafine-grain Ti and its alloys prepared by ECAP for biomedical applications[J]. Rare Metal Materials and Engineering, 2023, 52(5): 1673.
- [27] Gurao N P, Manivasagam G, Govindaraj P, Asokamani R, Suwas S. Effect of texture and grain size on bio-corrosion response of ultrafine-grained titanium[J]. Metallurgical and Materials Transactions A, 2013, 44(12): 5602.
- equal channel angular pressing(ECAP)
- Ti-25Nb-3Mo-3Zr-2Sn(TLM) titanium alloy
- twins
- corrosive properties
- Yang Xirong
- Wang Bingbing
- Qiang Meng
- Liu Xiaoyan
- Luo Lei
- Wang Jingzhong
- School of Metallurgical Engineering
- Xi'an University of Architecture and Technology
- Yang Xirong
- Wang Bingbing
- Qiang Meng
- Liu Xiaoyan
- Luo Lei
- Wang Jingzhong
- School of Metallurgical Engineering
- Xi'an University of Architecture and Technology